General specifications
| Product Name |
Eaton DS7 Soft starter
|
| Catalog Number |
134932
|
| Model Code |
DS7-342SX032N0-N
|
| EAN |
4015081317479
|
| Product Length/Depth |
118 mm
|
| Product Height |
150 mm
|
| Product Width |
45 mm
|
| Product Weight |
0.4 kg
|
| Certifications |
UL 508
UL File No.: E251034 CSA File No.: 2511305 GB 14048.6 IEC/EN 60947-4-2 CSA Class No.: 321106 CSA CE UkrSEPRO CSA-C22.2 No 14-05 UL C-Tick CSA22.2-14 CSA-C22.2 No 0-M91 |
| Global Catalog |
134932
|
| Product Type |
Soft starter
|
Product specifications
| Control voltage |
110/230 Vac control
|
| Phase |
Three-phase
|
| Special features |
Internal bypass
|
| Type |
Soft starter for three-phase loads
|
| Voltage rating |
110/230 V
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Fitted with: |
Internal bypass
Internal bypass contacts |
| Pollution degree |
2
|
| Class |
Other
|
| Climatic proofing |
Damp heat, constant, to IEC 60068-2-3
Damp heat, cyclic, to IEC 60068-2-30 |
| Connection to SmartWire-DT |
No
|
| Frame size |
FS2
|
| Altitude |
Above 1000 m with 1 % derating per 100 m
Max. 2000 m |
| Ambient operating temperature - max |
40 °C
|
| Ambient operating temperature - min |
-5 °C
|
| Ambient storage temperature - max |
60 °C
|
| Ambient storage temperature - min |
-25 °C
|
| Assigned motor power at 200/208 V, 60 Hz, 3-phase |
10 HP
|
| Assigned motor power at 220/230 V, 60 Hz, 3-phase |
10 HP
|
| Assigned motor power at 460/480 V, 60 Hz, 3-phase |
25 HP
|
| Equipment heat dissipation, current-dependent Pvid |
1.5 W
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
0 W
|
| Mains voltage - max |
480 V
|
| Mains voltage - min |
200 V
|
| Series |
Generation 7
|
| Output voltage |
250 V AC (relay outputs)
|
| Number of outputs |
2 Relay Outputs (TOR, Ready)
|
| Screwdriver size |
PZ2, 1 x 6 mm, Terminal screw, Standard screwdriver
0.6 x 5.5 mm/1 x 6 mm, Terminal screws, Control circuit cables |
| Voltage type |
AC
|
| Rated operational voltage (Ue) - min |
230 V
|
| Rated power three-phase motor, inline, at 230 V |
7.5 kW
|
| Rated power three-phase motor, inline, at 400 V |
15 kW
|
| Static heat dissipation, non-current-dependent Pvs |
1.5 W
|
| Voltage rating - max |
480 V
|
| Application |
|
| Protection |
Finger and back-of-hand proof, Protection against direct contact
|
| Mounting position |
Vertical
|
| Input current |
4 mA (at 230 V AC, Digital inputs)
|
| Drop-out voltage |
AC operated: 0 - 15 V, AC operated
|
| Overvoltage category |
II
|
| Degree of protection |
IP20
NEMA 1 |
| Current consumption |
1.6 mA, Control circuit, Digital inputs, External 24 V
50 mA, Control circuit, Regulator supply |
| Functions |
Single direction
Suppression of closing transients Potential isolation between power and control sections Min. ramp time 1 s - fast switching (semiconductor contactor) Suppression of DC components for motors Soft start function |
| Delay time |
0 - 30 s, Soft start function, Ramp times
|
| Overload cycle |
AC-53a: 3 - 5: 75 - 10
|
| Drop-out time |
350 ms, Control circuit, Digital Inputs, AC operated
|
| Pick-up voltage |
108 - 253 V AC
|
| Radio interference class |
Class A (EN 55011)
|
| Pick-up time |
250 ms at AC
|
| Rated control voltage (Uc) |
110 - 230 V AC
110 - 230 V AC (-15 %/+10 %) |
| Supply frequency |
50/60 Hz, fLN, Main circuit
|
| Terminal capacity (stranded) |
1 x (0.5 - 1.5) mm², Control circuit cables
2 x (0.5 - 1.0) mm², Control circuit cables 1 x 16 mm², Main cables |
| Rated control supply voltage (Us) at AC, 50 Hz - max |
230 V
|
| Rated control supply voltage (Us) at AC, 50 Hz - min |
110 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - max |
230 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - min |
110 V
|
| Rated operational current (Ie) at AC-11 |
1 A
|
| Rated operational current (Ie) at AC-53 |
32 A
|
| Rated operational current for specified heat dissipation (In) |
32 A
|
| Rated operational power at 220/230 V, 50 Hz |
7.5 kW
|
| Rated operational power at 400 V, 50 Hz |
15 kW
|
| Rated operational voltage (Ue) - max |
480 V
|
| Vibration resistance |
2M2 to EN 60721-3-2
|
| Ramp/run-up time |
1 - 30 s
|
| Shock resistance |
8 g, 11 ms, Mechanical
|
| Suitable for |
Branch circuits, (UL/CSA)
|
| Tightening torque |
3.2 Nm
1.2 Nm, Screw terminals, Control circuit cables |
| Short-circuit protection rating |
3 x 170M1366, Type „2“ coordination (additional with the fuses for coordination type „1“), Main conducting paths
PKM0-32 (+ CL-PKZ0), Type “1” coordination, Main conducting paths |
| Start voltage |
Min. 30 %, Soft start function, Start voltage = turn-off voltage
Max. 100 %, Soft start function, Start voltage = turn-off voltage |
| Terminal capacity (flexible with ferrule) |
1 x (0.5 - 1.5) mm², Control circuit cables
2 x (0.75 - 10) mm², Main cables 1 x (0.75 - 16) mm², Main cables 2 x (0.5 - 0.75) mm², Control circuit cables |
| Terminal capacity (solid) |
2 x (0.5 - 1.0) mm², Control circuit cables
2 x (0.75 - 10) mm², Main cables 1 x (0.5 - 2.5) mm², Control circuit cables 1 x (0.75 - 16) mm², Main cables |
| Terminal capacity (solid/stranded AWG) |
1 x (21 - 14), Control circuit cables
18 - 6, Main cables 2 x (21 - 18), Control circuit cables |
Politica de retur
Transport
Putem livra practic prin curier la orice adresa din Romania. Rețineți că există restricții pentru unele produse, iar unele produse nu pot fi expediate către destinații internaționale.