General specifications
| Product Name |
Eaton DS7 Soft starter
|
| Catalog Number |
134847
|
| EAN |
4015081316922
|
| Product Length/Depth |
94 mm
|
| Product Height |
130 mm
|
| Product Width |
45 mm
|
| Product Weight |
0.35 kg
|
| Compliances |
CE Marked
|
| Certifications |
UL 508
CSA Std. C22.2 No. 14-05 CSA Std. C22.2 No. 0-M91 IEC 60947-4-2 EN 60947-4-2 CSA File No.: 2511305 UL File No.: E251034 CSA-C22.2 No 0-M91 CSA Class No.: 321106 GB 14048.6 CSA-C22.2 No 14-05 IEC/EN 60947-4-2 CSA C-Tick CSA22.2-14 UL CE UkrSEPRO |
| Model Code |
DS7-340SX004N0-N
|
Features & Functions
| Fitted with: |
Internal bypass contacts
Internal bypass |
| Functions |
Potential isolation between power and control sections
Min. ramp time 1 s - fast switching (semiconductor contactor) Suppression of closing transients Single direction Soft start function Suppression of DC components for motors |
General
| Class |
Other
|
| Connection to SmartWire-DT |
No
|
| Degree of protection |
IP20
NEMA 1 |
| Frame size |
FS1
|
| Mains voltage - max |
480 V
|
| Mains voltage - min |
200 V
|
| Overvoltage category |
II
|
| Pollution degree |
2
|
| Radio interference class |
Class B (EN 55011)
|
| Suitable for |
Branch circuits, (UL/CSA)
|
| Type |
Soft starter for three-phase loads
|
| Voltage type |
AC/DC
|
Ambient conditions, mechanical
| Mounting position |
Vertical
|
| Shock resistance |
8 g, 11 ms, Mechanical
|
| Vibration resistance |
2M2 to EN 60721-3-2
|
Climatic environmental conditions
| Altitude |
Above 1000 m with 1 % derating per 100 m
Max. 2000 m |
| Ambient operating temperature - max |
40 °C
|
| Ambient operating temperature - min |
-5 °C
|
| Climatic proofing |
Damp heat, constant, to IEC 60068-2-3
Damp heat, cyclic, to IEC 60068-2-30 |
Main conducting paths
| Overload cycle |
AC-53a: 3 - 5: 75 - 10
|
| Rated operational current (Ie) at AC-53 |
4 A
|
| Rated operational voltage (Ue) - max |
480 V
|
| Rated operational voltage (Ue) - min |
230 V
|
| Short-circuit protection rating |
3 x 170M1359, Type „2“ coordination (additional with the fuses for coordination type „1“), Main conducting paths
PKM0-4 (+ CL-PKZ0), Type “1” coordination, Main conducting paths |
| Supply frequency |
50/60 Hz, fLN, Main circuit
|
| Voltage rating - max |
480 V
|
Motor rating
| Assigned motor power at 200/208 V, 60 Hz, 3-phase |
0.75 HP
|
| Assigned motor power at 220/230 V, 60 Hz, 3-phase |
1 HP
|
| Assigned motor power at 460/480 V, 60 Hz, 3-phase |
2 HP
|
| Rated operational power at 220/230 V, 50 Hz |
0.75 kW
|
| Rated operational power at 400 V, 50 Hz |
1.5 kW
|
Politica de retur
Transport
Putem livra practic prin curier la orice adresa din Romania. Rețineți că există restricții pentru unele produse, iar unele produse nu pot fi expediate către destinații internaționale.