Eaton DS7 Soft starter, 7 A, 200 - 480 V AC, 24 V AC/DC, Frame size FS1, Ambient temperature Operation -40 - +40 °C
Eaton DS7 Soft starter, 7 A, 200 - 480 V AC, 24 V AC/DC, Frame size FS1, Ambient temperature Operation -40 - +40 °C
COSTURILE LOCALE DE TRANSPORT SUNT DE 30 RON FARA TVA
| Product Name |
Eaton DS7 Soft starter
|
| Catalog Number |
171741
|
| EAN |
4015081680665
|
| Product Length/Depth |
94 mm
|
| Product Height |
130 mm
|
| Product Width |
45 mm
|
| Product Weight |
0.41 kg
|
| Certifications |
CSA-C22.2 No 0-M91
CSA22.2-14 GB 14048.6 CSA File No.: 2511305 UkrSEPRO UL File No.: E251034 CE CSA Class No.: 321106 CSA-C22.2 No 14-05 IEC/EN 60947-4-2 CSA UL UL 508 C-Tick |
| Model Code |
DS7-340SX007N0-L
|
Features & Functions
| Fitted with: |
Internal bypass
Internal bypass contacts |
| Functions |
Suppression of DC components for motors
Potential isolation between power and control sections Soft start function Suppression of closing transients Single direction Min. ramp time 1 s - fast switching (semiconductor contactor) |
General
| Class |
Other
|
| Connection to SmartWire-DT |
No
|
| Degree of protection |
IP20
NEMA 1 |
| Frame size |
FS1
|
| Mains voltage - max |
480 V
|
| Mains voltage - min |
200 V
|
| Overvoltage category |
II
|
| Pollution degree |
2
|
| Radio interference class |
Class B (EN 55011)
|
| Suitable for |
Branch circuits, (UL/CSA)
|
| Type |
Soft starter for three-phase loads
|
| Voltage type |
AC/DC
|
Ambient conditions, mechanical
| Mounting position |
Vertical
|
| Shock resistance |
8 g, 11 ms, Mechanical
|
| Vibration resistance |
2M2 to EN 60721-3-2
|
Climatic environmental conditions
| Altitude |
Above 1000 m with 1 % derating per 100 m
Max. 2000 m |
| Ambient operating temperature - max |
40 °C
|
| Ambient operating temperature - min |
-40 °C
|
| Climatic proofing |
Cold to EN 60068-2-1
Damp heat, constant, to IEC 60068-2-3 Damp heat, cyclic, to IEC 60068-2-30 |
Main conducting paths
| Overload cycle |
AC-53a: 3 - 5: 75 - 10
|
| Rated operational current (Ie) at AC-53 |
7 A
|
| Rated operational voltage (Ue) - max |
480 V
|
| Rated operational voltage (Ue) - min |
230 V
|
| Short-circuit protection rating |
PKM0-10 (+ CL-PKZ0), Type “1” coordination, Main conducting paths
3 x 170M1361, Type „2“ coordination (additional with the fuses for coordination type „1“), Main conducting paths |
| Supply frequency |
50/60 Hz, fLN, Main circuit
|
| Voltage rating - max |
480 V
|
Motor rating
| Assigned motor power at 200/208 V, 60 Hz, 3-phase |
2 HP
|
| Assigned motor power at 220/230 V, 60 Hz, 3-phase |
2 HP
|
| Assigned motor power at 460/480 V, 60 Hz, 3-phase |
5 HP
|
| Rated operational power at 220/230 V, 50 Hz |
1.5 kW
|
| Rated operational power at 400 V, 50 Hz |
3 kW
|