General specifications
| Product Name |
Eaton Moeller® series PKZM0 Motor-protective circuit-breaker
|
| Catalog Number |
189895
|
| EAN |
4015081878918
|
| Product Length/Depth |
76 mm
|
| Product Height |
93 mm
|
| Product Width |
45 mm
|
| Product Weight |
0.243 kg
|
| Compliances |
CE Marked
RoHS conform |
| Model Code |
PKZM0-0,25-EA
|
Features & Functions
| Actuator type |
Turn button
|
| Features |
Phase-failure sensitivity (according to IEC/EN 60947-4-1, VDE 0660 Part 102)
|
| Functions |
Phase failure sensitive
Motor protection |
| Number of poles |
Three-pole
|
General information
| Connection |
Screw terminals
|
| Lifespan, electrical |
100,000 operations
|
| Lifespan, mechanical |
100,000 Operations
|
| Mounting position |
Can be snapped on to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height.
|
| Operating frequency |
40 Operations/h
|
| Overvoltage category |
III
|
| Pollution degree |
3
|
| Product category |
Motor protective circuit breaker
|
| Product category |
Motor protective circuit breaker
|
| Protection |
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
|
| Rated impulse withstand voltage (Uimp) |
6000 V AC
|
| Shock resistance |
25 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
|
| Suitable for |
Branch circuit: Suitable for group installations, (UL/CSA)
Also motors with efficiency class IE3 |
| Temperature compensation |
-5 - 40 °C to IEC/EN 60947, VDE 0660
-25 - 55 °C, Operating range ≤ 0.25 %/K, residual error for T > 40° |
Climatic environmental conditions
| Altitude |
Max. 2000 m
|
| Ambient operating temperature (enclosed) - min |
-25 °C
|
| Ambient storage temperature - min |
-40 °C
|
| Ambient storage temperature - max |
80 °C
|
| Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
Terminal capacities
| Terminal capacity (solid) |
1 x (1 - 6) mm²
2 x (1 - 6) mm² |
| Terminal capacity (solid/stranded AWG) |
18 - 10
|
| Stripping length (main cable) |
10 mm
|
| Tightening torque |
1.7 Nm, Screw terminals, Main cable
|
Electrical rating
| Rated frequency - min |
50 Hz
|
| Rated frequency - max |
60 Hz
|
| Rated operational power at AC-3e, 220/230 V, 50 Hz |
0 kW
|
| Rated operational power at AC-3e, 380/400 V, 50 Hz |
0.06 kW
|
| Rated operational voltage (Ue) - min |
690 V
|
| Rated operational voltage (Ue) - max |
690 V
|
| Rated uninterrupted current (Iu) |
0.25 A
|
Short-circuit rating
| Rated short-circuit breaking capacity Icu at 400 V AC |
150 kA
|
| Rated short-circuit breaking capacity Ics at 400 V AC |
150 kA
|
| Rated short-circuit breaking capacity Icu at 440 V AC |
150 kA
|
| Rated short-circuit breaking capacity Ics at 440 V AC |
150 kA
|
| Rated short-circuit breaking capacity Icu at 500 V AC |
150 kA
|
| Rated short-circuit breaking capacity Ics at 500 V AC |
150 kA
|
| Rated short-circuit breaking capacity Icu at 690 V AC |
150 kA
|
| Rated short-circuit breaking capacity Ics at 690 V AC |
150 kA
|
| Short-circuit current rating (group protection) |
50 kA, 600 V High Fault, Fuse, SCCR (UL/CSA) with 600 A, 600 V High Fault, Fuse, SCCR (UL/CSA)
50 kA, 600 V High Fault, CB, SCCR (UL/CSA) with 600 A, 600 V High Fault, CB, SCCR (UL/CSA) |
| Short-circuit release |
Basic device fixed 15.5 x Iu
± 20% tolerance 3.9 A, Irm |
Switching capacity
| Switching capacity |
0.25 A, AC-3 up to 690 V
|
Trip blocks
| Overload release current setting - min |
0.16 A
|
| Overload release current setting - max |
0.25 A
|
Design verification
| Equipment heat dissipation, current-dependent Pvid |
5.15 W
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
1.7 W
|
| Rated operational current for specified heat dissipation (In) |
0.25 A
|
| Static heat dissipation, non-current-dependent Pvs |
0 W
|
Politica de retur
Transport
Putem livra practic prin curier la orice adresa din Romania. Rețineți că există restricții pentru unele produse, iar unele produse nu pot fi expediate către destinații internaționale.