FRBDM-C20/2/003-G/A
zoom_out_map
chevron_left chevron_right

FRBDM-C20/2/003-G/A

Electronic RCD/MCB combination, 20 A, 30 mA, MCB trip characteristic: C, 2p, RCD trip characteristic: A
EL Number (Norway)
1666107
High-quality residual current device/miniature circuit breaker combination, line voltage-dependent, contact position indicator red - green, terminal rear plug protection, tri-stable slide catch - enables removal from existing busbar system, comprehensive range of accessories suitable for subsequent installation, wide range of rated fault currents, rated operational currents up to 40 A, tripping characteristics B, C, D, rated breaking capacity 10 kA, suitable for outdoor use (on-site power and outdoor distribution board) up to -25 °C

437,77 lei Include TVA

361,79 lei Nu include TVA

COSTURILE LOCALE DE TRANSPORT SUNT DE 30 RON FARA TVA

10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements.
10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions Meets the product standard's requirements.
10.3 Degree of protection of assemblies Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard's requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Is the panel builder's responsibility.
10.8 Connections for external conductors Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility.
Application Switchgear for industrial and advanced commercial applications
Basic function Combined RCD/MCB devices
Current limiting class 3
Degree of protection IP20
Equipment heat dissipation, current-dependent 5 W
Fault current rating 0.03
Features Anti-nuisance tripping version
Frequency rating 50 Hz
Heat dissipation capacity 0
Heat dissipation per pole, current-dependent 0
Impulse withstand current Surge-proof, 3 kA
Leakage current type A
Number of poles Two-pole
Number of poles (protected) 2
Number of poles (total) 2
Operating ambient temperature hint Keep in mind the derating at temperatures higher than 40 °C
Overvoltage category III
Pollution degree 2
Product range FRBdM
Rated current 20
Rated fault currents of product range 10, 30, 100 MilliAmpere
Rated operational current for specified heat dissipation (In) 20
Rated short-circuit breaking capacity (EN 60947-2) 0
Rated switching capacity 10
Rated switching capacity (IEC/EN 61009) 10000
Release characteristic C
Sensitivity type Pulse-current sensitive
Static heat dissipation, non-current-dependent 0
Surge current capacity 3
Tripping Short time-delayed
Tripping characteristic C
Type RCBO
Voltage rating 240 V - 240 V
Voltage type AC
Width in number of modular spacings 2
Lungime 86 MM
Latime 37 MM
Inaltime 75 MM
Volum 238.65 CUC
Greutate 0.25 KG
Lungime 86 MM
Latime 37 MM
Inaltime 75 MM
Greutate 0.274 KG
EATON
168205

Politica de retur

 Puteți returna majoritatea articolelor noi, nedeschise în termen de 14 de zile de la livrare, pentru o rambursare completă. Vom plăti, de asemenea, costurile de transport pentru retur dacă returnarea este rezultatul unei erori noastre (ați primit un articol incorect sau defect etc.).

 Ar trebui să vă așteptați să primiți rambursarea în termen de doua săptămâni de la livrarea pachetului expeditorului returnat, cu toate acestea, în multe cazuri, veți primi o rambursare mai rapid. Această perioadă de timp include timpul de tranzit pentru a primi returnarea dvs. de la expeditor (5 până la 10 zile lucrătoare), timpul necesar pentru procesarea returnării dvs. după ce îl primim (3 până la 5 zile lucrătoare) și timpul necesar banca dvs. pentru a procesa cererea noastră de rambursare (5 până la 10 zile lucrătoare).

 Dacă trebuie să returnați un articol, pur și simplu conectați-vă la contul dvs., vizualizați comanda utilizând link-ul „Finalizare comenzi” din meniul Contul meu și faceți clic pe butonul Returnați articolele. Vă vom anunța prin e-mail cu privire la rambursarea dvs. după ce am primit și procesat articolul returnat.

 

Transport

 

Putem livra practic prin curier la orice adresa din Romania. Rețineți că există restricții pentru unele produse, iar unele produse nu pot fi expediate către destinații internaționale.

 Când plasați o comandă, vom estima datele de expediere și livrare pentru dvs. în funcție de disponibilitatea articolelor dvs. și de opțiunile de livrare pe care le alegeți. În funcție de furnizorul de transport pe care îl alegeți, este posibil ca estimările datei de expediere să apară pe pagina de oferte de livrare.

chat Comentarii (0)