NHI-E-11-PKZ0 - Standard auxiliary contact, NHI-E, 1 N/O, 1 NC,
zoom_out_map
chevron_left chevron_right

NHI-E-11-PKZ0 - Standard auxiliary contact, NHI-E, 1 N/O, 1 NC,

22,61 lei Include TVA

19,00 lei Nu include TVA

Livrare din STOC
check DISPONIBIL

COSTURILE LOCALE DE TRANSPORT SUNT DE 25 RON FARA TVA

Product range
Accessories
Accessories
Standard auxiliary contact
Can be fitted to the front
Terminal designation differs to that of an auxiliary contact that can be fitted to the side
Contacts
N/O = Normally open
1 N/O
N/C = Normally closed
1 NC
Contact diagram
121U004
Contact sequence
121S012
Connection technique
Screw terminals
For use with
PKZ0(4) standard auxiliary contacts
For use with
PKZM01
PKZM0
PKZM4
PKZM0-T
PKM0
PKE
Notes
Can be fitted to:
Motor protective circuit-breaker
Transformer-protective circuit-breaker
Motor protective circuit breaker for starter combinations
(From serial number 01)
45 mm (PKZM0 and PKZM01) or 55 mm (PKZM4) widths of the motor-protective circuit-breakers remain unchanged.

TECHNICAL DATA

Auxiliary contacts
Rated impulse withstand voltage [Uimp]
4000 V AC
Overvoltage category/pollution degree
III/3
Rated operational voltage [Ue] [Ue]
440 V AC
Rated operational voltage [Ue] [Ue ]
250 V DC
Safe isolation to EN 61140Between auxiliary contacts and main contacts
690 V AC
Rated operational current [Ie ]AC-15220 - 240 V [Ie]
1 A
Rated operational current [Ie ]DC-13 L/R - 100 ms24 V [Ie ]
2 A
LifespanLifespan, mechanical [Operations]
> 0.1 x 106
LifespanLifespan, electrical [Operations]
0.1 x 106
Control circuit reliability [Failure rate]
<10-8, < one failure at 100 million operations
(at Ue = 24 V DC, Umin = 17 V, Imin = 5.4 mA) λ
Short-circuit rating without weldingFuse
10 A gG/gL
Terminal capacities
Solid or flexible conductor, with ferrule
0,75 - 1,5 mm2
Solid or stranded
18 - 16 AWG
Rating data for approved types
Pilot DutyAC operated
E150
General UseDC
250 V
General UseDC
0.5 A

DESIGN VERIFICATION AS PER IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
1 A
Heat dissipation per pole, current-dependent [Pvid]
0.01 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+55 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

TECHNICAL DATA ETIM 8.0

Low-voltage industrial components (EG000017) / Auxiliary contact block (EC000041)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Auxiliary switch block (ecl@ss10.0.1-27-37-13-02 [AKN342013])
Number of contacts as change-over contact
0
Number of contacts as normally open contact
1
Number of contacts as normally closed contact
1
Number of fault-signal switches
0
Rated operation current Ie at AC-15, 230 V
1 A
Type of electric connection
Screw connection
Model
Top mounting
Mounting method
Front fastening
Lamp holder
None

APPROVALS

Product Standards
UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking
UL File No.
E36332
UL Category Control No.
NLRV
CSA File No.
165628
CSA Class No.
3211-05
North America Certification
UL listed, CSA certified
Specially designed for North America
No

CHARACTERISTICS

121O003
Accessories
1: Motor-protective circuit-breakers
2: Trip-indicating auxiliary contact

DIMENSIONS

1210DIM-101
PKZM0-…(+NHI-E-…-PKZ0)
PKZM0-…-T(+NHI-E-…-PKZ0)
PKM0-…(+NHI-E-…-PKZ0)
121X001
EATON
082882

Politica de retur

 Puteți returna majoritatea articolelor noi, nedeschise în termen de 14 de zile de la livrare, pentru o rambursare completă. Vom plăti, de asemenea, costurile de transport pentru retur dacă returnarea este rezultatul unei erori noastre (ați primit un articol incorect sau defect etc.).

 Ar trebui să vă așteptați să primiți rambursarea în termen de doua săptămâni de la livrarea pachetului expeditorului returnat, cu toate acestea, în multe cazuri, veți primi o rambursare mai rapid. Această perioadă de timp include timpul de tranzit pentru a primi returnarea dvs. de la expeditor (5 până la 10 zile lucrătoare), timpul necesar pentru procesarea returnării dvs. după ce îl primim (3 până la 5 zile lucrătoare) și timpul necesar banca dvs. pentru a procesa cererea noastră de rambursare (5 până la 10 zile lucrătoare).

 Dacă trebuie să returnați un articol, pur și simplu conectați-vă la contul dvs., vizualizați comanda utilizând link-ul „Finalizare comenzi” din meniul Contul meu și faceți clic pe butonul Returnați articolele. Vă vom anunța prin e-mail cu privire la rambursarea dvs. după ce am primit și procesat articolul returnat.

 

Transport

 

Putem livra practic prin curier la orice adresa din Romania. Rețineți că există restricții pentru unele produse, iar unele produse nu pot fi expediate către destinații internaționale.

 Când plasați o comandă, vom estima datele de expediere și livrare pentru dvs. în funcție de disponibilitatea articolelor dvs. și de opțiunile de livrare pe care le alegeți. În funcție de furnizorul de transport pe care îl alegeți, este posibil ca estimările datei de expediere să apară pe pagina de oferte de livrare.

chat Comentarii (0)